Low Frequency Noise and Vibration Eliminated

Low Frequency Noise and Vibration Eliminated

 

 

Tough problem:

Two vibration screens running side by side were causing the main administration office at a client’s processing plant to shake and there was a persistent and annoying low frequency noise inside the office.

Practical Solution:

SVT conducted both noise and vibration measurements to determine the physical mechanisms generating the noise and vibration.

The two screens generated a very low frequency beat. SVT proposed linking the drive shafts of the two vibration screens together with a splined shaft and adjusting the phase between the screens until the noise from each screen cancelled each other out.

The Bottom Line:

The noise level inside the admin building dropped by 20 dB. The building stopped shaking and the noise was almost imperceptible.